Masimo (NASDAQ: MASI) today announced the findings of an abstract recently presented at ANESTHESIOLOGY® 2020, the Annual Meeting of the American Society of Anesthesiologists (ASA). In this independent, retrospective study, researchers investigated whether Masimo ORi™ (Oxygen Reserve Index) could predict whether children with obstructive sleep apnea syndrome (OSAS) undergoing tonsillectomy required postoperative oxygen therapy.
This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20201011005050/en/
ORi, available outside the U.S., is a noninvasive and continuous parameter intended to provide insight into a patient’s oxygen status during moderate hyperoxia. Enabled by the multi-wavelength rainbow® Pulse CO-Oximetry platform, ORi is provided alongside oxygen saturation (SpO2 ), a clinically proven Masimo SET® pulse oximetry measurement.
Dr. Yoshimi Inagaki and colleagues at Tottori University in Yonago, Japan sought to determine whether Masimo ORi could serve as a useful predictor of the need for postoperative oxygen therapy (POT). They enrolled 45 pediatric patients with OSAS, ranging from 7 to 120 months, who were anesthetized with sevoflurane and monitored with ORi while undergoing tonsillectomy.
Of the 45 patients, 16 required POT. For those 16, the mean lowest ORi and SpO2 values were 0.28 and 93%, respectively. For the remaining patients, who did not receive POT, the mean lowest values were 0.64 and 97%, respectively. The researchers calculated sensitivity and specificity for ORi predicting when POT would not be needed of 0.815 (95% confidence interval 0.5435 – 0.9595) and 0.9310 (95% confidence interval 0.7723 – 0.9915), respectively.
The researchers concluded that ORi is “likely to become an index of POT in pediatric patients with OSAS.” They also noted, “In children with OSAS, [the] requirement of POT following tonsillectomy and adenoidectomy is probably able to be predicted on the basis of the results of this retrospective cohort study.”
ORi has not received FDA 510(k) clearance and is not available for sale in the United States.
@Masimo | #Masimo
About Masimo
Masimo (NASDAQ: MASI) is a global medical technology company that develops and produces a wide array of industry-leading monitoring technologies, including innovative measurements, sensors, patient monitors, and automation and connectivity solutions. Our mission is to improve patient outcomes and reduce the cost of care. Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry, introduced in 1995, has been shown in over 100 independent and objective studies to outperform other pulse oximetry technologies.2 Masimo SET® has also been shown to help clinicians reduce severe retinopathy of prematurity in neonates,3 improve CCHD screening in newborns,4 and, when used for continuous monitoring with Masimo Patient SafetyNet™ in post-surgical wards, reduce rapid response team activations, ICU transfers, and costs.5-8 Masimo SET® is estimated to be used on more than 200 million patients in leading hospitals and other healthcare settings around the world,9 and is the primary pulse oximetry at 9 of the top 10 hospitals according to the 2020-21 U.S. News and World Report Best Hospitals Honor Roll.10 Masimo continues to refine SET® and in 2018, announced that SpO2 accuracy on RD SET® sensors during conditions of motion has been significantly improved, providing clinicians with even greater confidence that the SpO2 values they rely on accurately reflect a patient’s physiological status. In 2005, Masimo introduced rainbow® Pulse CO-Oximetry technology, allowing noninvasive and continuous monitoring of blood constituents that previously could only be measured invasively, including total hemoglobin (SpHb® ), oxygen content (SpOC™), carboxyhemoglobin (SpCO® ), methemoglobin (SpMet® ), Pleth Variability Index (PVi® ), RPVi™ (rainbow® PVi), and Oxygen Reserve Index (ORi™). In 2013, Masimo introduced the Root® Patient Monitoring and Connectivity Platform, built from the ground up to be as flexible and expandable as possible to facilitate the addition of other Masimo and third-party monitoring technologies; key Masimo additions include Next Generation SedLine® Brain Function Monitoring, O3® Regional Oximetry, and ISA™ Capnography with NomoLine® sampling lines. Masimo’s family of continuous and spot-check monitoring Pulse CO-Oximeters® includes devices designed for use in a variety of clinical and non-clinical scenarios, including tetherless, wearable technology, such as Radius-7® and Radius PPG™, portable devices like Rad-67™, fingertip pulse oximeters like MightySat® Rx, and devices available for use both in the hospital and at home, such as Rad-97® . Masimo hospital automation and connectivity solutions are centered around the Masimo Hospital Automation™ platform, and include Iris Gateway® , Patient SafetyNet, Replica™, Halo ION™, UniView™, UniView: 60™, and Masimo SafetyNet™. Additional information about Masimo and its products may be found at www.masimo.com . Published clinical studies on Masimo products can be found at www.masimo.com/evidence/featured-studies/feature/ .
ORi and RPVi have not received FDA 510(k) clearance and are not available for sale in the United States. The use of the trademark Patient SafetyNet is under license from University HealthSystem Consortium.
References
- Inagaki Y, Kitagawa Y, Otsuki A. Oxygen Reserve Index Predicts Postoperative Oxygen Requirement after Tonsillectomy in Children with Obstructive Sleep Apnea Syndrome. Proceedings from the ASA 2020 Annual Meeting. Abstract #A4091. Accessed 10/8/20 at https://epostersonline.com/asa2020/node/739?view=true .
- Published clinical studies on pulse oximetry and the benefits of Masimo SET® can be found on our website at http://www.masimo.com . Comparative studies include independent and objective studies which are comprised of abstracts presented at scientific meetings and peer-reviewed journal articles.
- Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
- de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;Jan 8;338.
- Taenzer A et al. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology . 2010:112(2):282-287.
- Taenzer A et al. Postoperative Monitoring – The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter . Spring-Summer 2012.
- McGrath S et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation. The Joint Commission Journal on Quality and Patient Safety . 2016 Jul;42(7):293-302.
- McGrath S et al. Inpatient Respiratory Arrest Associated With Sedative and Analgesic Medications: Impact of Continuous Monitoring on Patient Mortality and Severe Morbidity. J Patient Saf. 2020 14 Mar. DOI: 10.1097/PTS.0000000000000696.
- Estimate: Masimo data on file.
- http://health.usnews.com/health-care/best-hospitals/articles/best-hospitals-honor-roll-and-overview .
Forward-Looking Statements
This press release includes forward-looking statements as defined in Section 27A of the Securities Act of 1933 and Section 21E of the Securities Exchange Act of 1934, in connection with the Private Securities Litigation Reform Act of 1995. These forward-looking statements include, among others, statements regarding the potential effectiveness of Masimo ORi™. These forward-looking statements are based on current expectations about future events affecting us and are subject to risks and uncertainties, all of which are difficult to predict and many of which are beyond our control and could cause our actual results to differ materially and adversely from those expressed in our forward-looking statements as a result of various risk factors, including, but not limited to: risks related to our assumptions regarding the repeatability of clinical results; risks related to our belief that Masimo's unique noninvasive measurement technologies, including Masimo ORi, contribute to positive clinical outcomes and patient safety; risks related to our belief that Masimo noninvasive medical breakthroughs provide cost-effective solutions and unique advantages; risks related to COVID-19; as well as other factors discussed in the "Risk Factors" section of our most recent reports filed with the Securities and Exchange Commission ("SEC"), which may be obtained for free at the SEC's website at www.sec.gov . Although we believe that the expectations reflected in our forward-looking statements are reasonable, we do not know whether our expectations will prove correct. All forward-looking statements included in this press release are expressly qualified in their entirety by the foregoing cautionary statements. You are cautioned not to place undue reliance on these forward-looking statements, which speak only as of today's date. We do not undertake any obligation to update, amend or clarify these statements or the "Risk Factors" contained in our most recent reports filed with the SEC, whether as a result of new information, future events or otherwise, except as may be required under the applicable securities laws.
View source version on businesswire.com: https://www.businesswire.com/news/home/20201011005050/en/
Link:
About Business Wire
Subscribe to releases from Business Wire
Subscribe to all the latest releases from Business Wire by registering your e-mail address below. You can unsubscribe at any time.
Latest releases from Business Wire
NetApp Helps Customers Accelerate Adoption of Latest VMware Cloud Foundation Innovations2.9.2026 22:30:00 CEST | Press release
NetApp solutions validated to support VCF 9.1, giving mutual customers access to a modern private cloud with enterprise-grade data management, cyber resilience, and cost-efficient scaling NetApp® (NASDAQ: NTAP), the Intelligent Data Infrastructure company, announced new capabilities in NetApp ONTAP® have been tested and validated to support VMware Cloud Foundation (VCF) 9.1, giving customers an optimized and secure data infrastructure foundation for their private and hybrid clouds. By combining the advanced capabilities of VCF 9.1 with cost-effective and enterprise data management with built-in security features from NetApp, including safeguarding data against ransomware attacks with rapid recovery, mutual customers can lower costs and accelerate the deployment of their AI software into production. VMware Cloud Foundation 9.1 provides enterprises with a unified private cloud platform for running both traditional and modern workloads. NetApp's solutions are tested and validated to suppo
Venture Global Announces Closing of $3,000,000,000 364-Day Senior Secured Revolving Credit Facility2.9.2026 22:30:00 CEST | Press release
Venture Global, Inc. (“Venture Global”) announced today that its subsidiary Venture Global LNG, Inc. (“VGLNG”) has entered into a new, $3,000,000,000 364-day revolving credit facility (the “Facility”). Venture Global expects to use the proceeds from borrowings under the Facility for general corporate purposes of VGLNG and its subsidiaries, including to fund certain project costs for the CP2 and Plaquemines bolt-on expansions prior to their respective FIDs. Bank of America, N.A. served as Coordinating Lead Arranger and Sole Bookrunner and will also serve as Administrative Agent. BBVA, Goldman Sachs, ING, J.P. Morgan, Mizuho, MUFG, NBC, RBC, Scotia, SMBC, U.S. Bank, and Wells Fargo served as Coordinating Lead Arrangers and Barclays, Santander, and Deutsche Bank served as Joint Lead Arrangers. About Venture Global Venture Global is an American producer and exporter of low-cost U.S. liquefied natural gas (LNG) with over 100 MTPA of capacity in production, construction, or development. Vent
Invivoscribe Begins Commercial Shipments of PrepQuant™ Systems, Enabling High-Sensitivity Sample Preparation for MRD Testing2.9.2026 21:31:00 CEST | Press release
New automated platform is designed to improve the quality, efficiency, and consistency of DNA extraction and concentration from large-volume blood and plasma samples, supporting downstream assays capable of detecting disease-associated signals at MRD sensitivity levels. Invivoscribe®, a global leader in precision diagnostics and measurable residual disease (MRD) testing, today announced that commercial shipments of the PrepQuant™ System have begun in North America. First unveiled at the American Association for Cancer Research Annual Meeting in April 2026, PrepQuant is now being delivered to customers, marking the platform's progression from development and validation into commercial deployment. The commercial milestone extends Invivoscribe's capabilities into laboratory instrumentation and addresses a critical bottleneck in highly sensitive molecular testing: efficiently recovering, concentrating, and quantifying DNA from larger blood and plasma inputs. PrepQuant is assay agnostic, de
C.H. Guenther Opens Centre of Excellence in Coventry, UK to Accelerate Bakery Innovation and Support Future Manufacturing Growth Across UK and Europe2.9.2026 18:00:00 CEST | Press release
C.H. Guenther & Son LLC (“C.H. Guenther” or “CHG”), a leading food manufacturer, has opened a new Centre of Excellence (the “Centre”) at its flagship Coventry bakery, creating a dedicated innovation and customer collaboration hub designed to accelerate the development of premium bakery products across the UK and Europe. The new facility has been designed to support CHG’s customers including leading global quick service restaurants, foodservice operators and retailers as they develop, test and refine new bakery products. This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20260902696890/en/ The purpose-built, 172-square-metre Centre of Excellence brings together a commercial-scale bakery, customer demonstration kitchen, sensory evaluation facilities, innovation suite and dedicated collaboration spaces in one specialized location. Designed to support and accelerate product development from concept through to commercial manufacturing,
Record Asset Management Enters New Phase of Growth2.9.2026 17:35:00 CEST | Press release
Record Asset Management GmbH (“RAM”), a subsidiary of London-listed Record plc (“Record” or the “Group”), is pleased to announce that it is now operating cashflow positive, thereby marking a transition from its investment phase into a growth business within the Group, and a significant milestone towards sustainable profitability. RAM is the European asset management arm of Record, the London-listed specialist investment group managing USD 122 billion of assets on behalf of institutional clients worldwide. Record's client base comprises pension funds, foundations, sovereign institutions and other asset managers, with whom the Group has built long-standing relationships through its focus on bespoke investment and risk management solutions. RAM was established as a sister company to Record’s core currency business and obtained its BaFin license in 2022. RAM has grown rapidly in the last two years and has developed into a diversified private markets platform with dedicated infrastructure e
In our pressroom you can read all our latest releases, find our press contacts, images, documents and other relevant information about us.
Visit our pressroom