Business Wire

MASIMO

Share
New Study Investigates the Ability of Masimo ORi™ to Provide Early Warning of Hypoxemia During Endotracheal Intubation in ICU Patients

Masimo (NASDAQ: MASI) announced today the findings of a prospective, blinded observational study published in Annals of Intensive Care in which Dr. Jean-Baptiste Lascarrou and colleagues at the Centre Hospitalier Universitaire in Nantes, France evaluated the ability of Masimo ORi™ to predict mild hypoxemia during endotracheal intubation (ETI) in ICU patients.1 They concluded that the time between decrease in ORi and subsequent decrease in oxygen saturation (SpO2 ) “may allow preventive action,” and that a higher ORi value during preoxygenation was “independently protective against hypoxemia.”

This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20210905005031/en/

ORi, available outside the U.S., is a noninvasive and continuous trending index that extends oxygen monitoring on patients on supplemental oxygen. Enabled by the multi-wavelength rainbow® Pulse CO-Oximetry platform, ORi is provided alongside oxygen saturation (SpO2 ) measured by clinically proven Masimo SET® pulse oximetry.

Noting the importance of optimizing preoxygenation in patients needing ETI, the researchers sought to evaluate whether ORi could provide early warning of impending hypoxemia during the procedure, because ORi “supplies information beyond the range explored by SpO2. ” Of the 51 patients who met the inclusion criteria, ORi (alongside SpO2 ) was monitored using Masimo Radical-7® Pulse CO-Oximeters® and rainbow® fingertip sensors when preoxygenation began. Values were recorded every two seconds, and attending clinicians were not aware of these values. The primary endpoint measured was the time between ORi decreasing below 0.4 and the onset of mild hypoxemia (defined as SpO2 < 97%). Secondarily, the investigators evaluated whether a decline in ORi during preoxygenation predicted the occurrence of mild hypoxemia during ETI.

Analyzing areas under the ROC curve, the researchers found that ORi during preoxygenation predicted SpO2 < 97% during intubation (0.73; 95% confidence interval of 0.58 – 0.88). By contrast, SpO2 at the end of preoxygenation was “poorly predictive” (0.54; 95% CI 0.40 – 0.67). Using univariate analysis, they found that a higher ORi value during preoxygenation was associated with a less frequent occurrence of SpO2 < 97% (odds ratio of 0.09; 95% CI 0.01 – 0.69, p = 0.0199) and that “the highest ORi value during preoxygenation remained significantly associated with a lower risk of SpO2 < 97% during ETI, after adjustment for ETI duration and BMI (odds ratio of 0.76; 95% CI 0.61 – 0.95, p = 0.0141).”

The researchers concluded, “The median time between the ORi decrease below 0.4 and the SpO2 decrease below 97% during the apneic period was 81 seconds [34–146]. A higher ORi during preoxygenation was independently associated with a lower risk of mild hypoxemia (SpO2 < 97%).”

The researchers noted that the median 81 seconds of forewarning “may allow immediate intubation, early face-mask ventilation, insertion of a supraglottic device, or a call for help in the event of intubation difficulties.” In addition, they noted that “ORi monitoring can help identify patients who do not increase their oxygen reserve despite preoxygenation and are therefore at [increased] risk of desaturation during ETI. These patients may benefit from a longer preoxygenation period and/or a change in device.” The authors further noted that “an ORi decline might lead to the detection of a fault in the preoxygenation technique such as an insufficient oxygen flow rate or major leaks.”

As a study limitation, the authors noted that their findings cannot be generalized to ICU patients who did not meet the inclusion criteria, as those patient cohorts remain to be evaluated. The inclusion criteria for this study were ICU admission with a need for ETI and an SpO2 /FiO2 ratio above 214. The SpO2 /FiO2 ratio was measured during noninvasive ventilation or high-flow oxygen therapy; for conventional oxygen therapy, the fraction of inspired oxygen (FiO2 ) was calculated as FiO2 = 0.21 + O2 [rate in L/min] x 0.03.

ORi has not received FDA 510(k) clearance and is not available for sale in the United States.

@Masimo | #Masimo

About Masimo

Masimo (NASDAQ: MASI) is a global medical technology company that develops and produces a wide array of industry-leading monitoring technologies, including innovative measurements, sensors, patient monitors, and automation and connectivity solutions. Our mission is to improve patient outcomes, reduce the cost of care, and take noninvasive monitoring to new sites and applications. Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry, introduced in 1995, has been shown in over 100 independent and objective studies to outperform other pulse oximetry technologies.2 Masimo SET® has also been shown to help clinicians reduce severe retinopathy of prematurity in neonates,3 improve CCHD screening in newborns,4 and, when used for continuous monitoring with Masimo Patient SafetyNet™ in post-surgical wards, reduce rapid response team activations, ICU transfers, and costs.5-8 Masimo SET® is estimated to be used on more than 200 million patients in leading hospitals and other healthcare settings around the world,9 and is the primary pulse oximetry at 9 of the top 10 hospitals as ranked in the 2021-22 U.S. News and World Report Best Hospitals Honor Roll.10 Masimo continues to refine SET® and in 2018, announced that SpO2 accuracy on RD SET® sensors during conditions of motion has been significantly improved, providing clinicians with even greater confidence that the SpO2 values they rely on accurately reflect a patient’s physiological status. In 2005, Masimo introduced rainbow® Pulse CO-Oximetry technology, allowing noninvasive and continuous monitoring of blood constituents that previously could only be measured invasively, including total hemoglobin (SpHb® ), oxygen content (SpOC™), carboxyhemoglobin (SpCO® ), methemoglobin (SpMet® ), Pleth Variability Index (PVi® ), RPVi™ (rainbow® PVi), and Oxygen Reserve Index (ORi™). In 2013, Masimo introduced the Root® Patient Monitoring and Connectivity Platform, built from the ground up to be as flexible and expandable as possible to facilitate the addition of other Masimo and third-party monitoring technologies; key Masimo additions include Next Generation SedLine® Brain Function Monitoring, O3® Regional Oximetry, and ISA™ Capnography with NomoLine® sampling lines. Masimo’s family of continuous and spot-check monitoring Pulse CO-Oximeters® includes devices designed for use in a variety of clinical and non-clinical scenarios, including tetherless, wearable technology, such as Radius-7® and Radius PPG™, portable devices like Rad-67® , fingertip pulse oximeters like MightySat® Rx, and devices available for use both in the hospital and at home, such as Rad-97® . Masimo hospital automation and connectivity solutions are centered around the Masimo Hospital Automation™ platform, and include Iris® Gateway, iSirona™, Patient SafetyNet, Replica™, Halo ION™, UniView® , UniView :60™, and Masimo SafetyNet™. Additional information about Masimo and its products may be found at www.masimo.com . Published clinical studies on Masimo products can be found at www.masimo.com/evidence/featured-studies/feature/ .

ORi and RPVi have not received FDA 510(k) clearance and are not available for sale in the United States. The use of the trademark Patient SafetyNet is under license from University HealthSystem Consortium.

References

  1. Hille H, Le Thuaut A, Canet E, Lemarie J, Crosby L, Ottavy G, Garret C, Martin M, Seguin A, Lamouche-Wilquin P Morin J, Zambon O, Miaihle AF, Reignier J, Lascarrou JB. Oxygen reserve index for noninvasive early hypoxemia detection during endotracheal intubation in intensive care: the prospective observational NESOI study. Ann. Intensive Care . 2021 11:112. DOI: 10.1186/s13613-021-00903-8.
  2. Published clinical studies on pulse oximetry and the benefits of Masimo SET® can be found on our website at http://www.masimo.com . Comparative studies include independent and objective studies which are comprised of abstracts presented at scientific meetings and peer-reviewed journal articles.
  3. Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
  4. de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;Jan 8;338.
  5. Taenzer A et al. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology . 2010:112(2):282-287.
  6. Taenzer A et al. Postoperative Monitoring – The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter . Spring-Summer 2012.
  7. McGrath S et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation. The Joint Commission Journal on Quality and Patient Safety . 2016 Jul;42(7):293-302.
  8. McGrath S et al. Inpatient Respiratory Arrest Associated With Sedative and Analgesic Medications: Impact of Continuous Monitoring on Patient Mortality and Severe Morbidity. J Patient Saf. 2020 14 Mar. DOI: 10.1097/PTS.0000000000000696.
  9. Estimate: Masimo data on file.
  10. http://health.usnews.com/health-care/best-hospitals/articles/best-hospitals-honor-roll-and-overview .

Forward-Looking Statements

This press release includes forward-looking statements as defined in Section 27A of the Securities Act of 1933 and Section 21E of the Securities Exchange Act of 1934, in connection with the Private Securities Litigation Reform Act of 1995. These forward-looking statements include, among others, statements regarding the potential effectiveness of Masimo ORi™. These forward-looking statements are based on current expectations about future events affecting us and are subject to risks and uncertainties, all of which are difficult to predict and many of which are beyond our control and could cause our actual results to differ materially and adversely from those expressed in our forward-looking statements as a result of various risk factors, including, but not limited to: risks related to our assumptions regarding the repeatability of clinical results; risks that findings in the new study on Masimo ORi's ability to predict hypoxemia during ETI cannot be generalized; risks that researchers’ conclusion on the practical applications of Masimo ORi’s forewarning ability may not be accurate; risks related to our belief that Masimo's unique noninvasive measurement technologies, including Masimo ORi, contribute to positive clinical outcomes and patient safety; risks related to our belief that Masimo noninvasive medical breakthroughs provide cost-effective solutions and unique advantages; risks related to COVID-19; as well as other factors discussed in the "Risk Factors" section of our most recent reports filed with the Securities and Exchange Commission ("SEC"), which may be obtained for free at the SEC's website at www.sec.gov . Although we believe that the expectations reflected in our forward-looking statements are reasonable, we do not know whether our expectations will prove correct. All forward-looking statements included in this press release are expressly qualified in their entirety by the foregoing cautionary statements. You are cautioned not to place undue reliance on these forward-looking statements, which speak only as of today's date. We do not undertake any obligation to update, amend or clarify these statements or the "Risk Factors" contained in our most recent reports filed with the SEC, whether as a result of new information, future events or otherwise, except as may be required under the applicable securities laws.

Link:

ClickThru

About Business Wire

Business Wire
Business Wire
101 California Street, 20th Floor
CA 94111 San Francisco

http://businesswire.com

Subscribe to releases from Business Wire

Subscribe to all the latest releases from Business Wire by registering your e-mail address below. You can unsubscribe at any time.

Latest releases from Business Wire

Aptiv Powers Intelligent Edge Applications From Automotive to Robotics at CES 20265.1.2026 07:01:00 CET | Press release

Showcase Features Aptiv Technologies Enabling Intelligent Cars, Commercial Vehicles, Robots, and Other Mission Critical ApplicationsImmersive Demos Highlight End-to-End AI for Autonomy, Personalized User Experience and Extensive Connectivity Aptiv PLC (NYSE: APTV),a global industrial technology company, will showcase at CES 2026 how its intelligent edge solutions enable devices to sense, think, and act in real time—while continuously optimizing performance throughout their lifecycle. This approach brings advanced computing and artificial intelligence closer to where data is generated, unlocking AI-driven solutions for transportation, robotics, aerospace, and beyond. This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20260104888341/en/ Aptiv Powers the Intelligent Edge from Automotive to Robotics at CES 2026 By processing data locally at the edge, rather than relying solely on centralized cloud systems, Aptiv’s solutions enable fas

Belkin styrker beskyttelsen af hverdagsenheder med en ny serie skærmbeskyttere og et Wear & Tear-program4.1.2026 18:00:00 CET | Pressemeddelelse

Belkin lancerer syv nye skærmbeskyttere, der er udviklet med proprietær Nano-Titan-teknologi for øget styrke mod daglige fald og ridser Et Wear and Tear-program skaber ro i sindet for forbrugere, der ønsker at udskifte deres produkter Forbrugerne kan nu personalisere deres skærmbeskyttere med Screen Skinz Belkin, et førende mærke inden for forbrugerelektronik i over 40 år, annoncerer i dag en ny klasse af løsninger til skærmbeskyttelse, et strategisk partnerskab og et helt nyt wear-and-tear-program, der styrker virksomhedens engagement i at beskytte enheder og give forbrugerne tryghed. Lanceringen omfatter syv nye skærmbeskyttere, et partnerskab med ScreenSkinz vedrørende personalisering, og et program til udskiftning af skærmbeskyttere beregnet til at give brugerne varig ro i sindet og sikre, at de produkter, de elsker, forbliver trygge, sikre og i den bedste form. Mød ScreenForce Titan-serien: Det ultimative inden for fuldskærmsbeskyttelse Titan SmartShield Titan SmartShield fungerer

Belkin præsenterer næste generation af opladere, strømtilbehør til gaming og meget mere på CES 20264.1.2026 18:00:00 CET | Pressemeddelelse

Belkin lancerer nye trådløse Qi2-opladere, powerbanks med høj kapacitet, kraftfulde hubs samt et opladningsetui til Nintendo Switch 2, der får debut på CES 2026 Belkin, et førende mærke inden for forbrugerelektronik i over 40 år, annoncerede i dag en ny serie af tilbehør, der er designet til at styrke, beskytte og forbedre den måde, folk arbejder, leger og er forbundet på. Den nye kollektion, som debuterer på CES 2026, omfatter avancerede powerbanks, Qi2 25 W trådløse opladere, en trådløs HDMI-dongle til problemfri deling af indhold og et opladningsetui af næste generation til Nintendo Switch 2. Der er multimedier i denne pressemeddelelse. Se hele meddelelsen her: https://www.businesswire.com/news/home/20260104854623/da/ Belkin unveils new products at CES 2026 Gaming Charging Case Pro til Nintendo Switch 2 (model ENA003) Udviklet til den ultimative gamingoplevelse på farten leverer Pro-etuiet strøm, beskyttelse og mobilitet samlet i én førsteklasses løsning. En udtagelig powerbank på 1

SINOVAC Provides Update on Antigua High Court Order and Auditor Engagement4.1.2026 16:13:00 CET | Press release

Sinovac Biotech Ltd. (NASDAQ: SVA) (“SINOVAC” or the “Company”), a leading provider of biopharmaceutical products in China, today provided an update on the Antigua High Court’s interlocutory order governing the Company’s board composition and corporate actions pending trial, and announced the engagement of Zhonghua Certified Public Accountants LLP (“Zhonghua”), an affiliate of the global accounting network UHY International, as the Company’s independent auditor and registered public accounting firm. Update on Antigua High Court Order Further to the order issued by the Antigua High Court (the “Court”) previously disclosed by the Company in a press release dated December 17, 2025, the Court has updated its order to provide that directors Mr. Simon Anderson, Mr. Shan Fu, Mr. Shuge Jiao, Dr. Chiang Li, Mr. Yuk Lam Lo, Mr. Yumin Qiu, Mr. Yu Wang, Ms. Rui-Ping Xiao, Mr. Andrew Y. Yan and Mr. Weidong Yin (collectively, the “Board”), will comprise the Board of the Company until the trial liste

Sinovac Receives Nasdaq Notification Regarding Late Filing of 2025 Half-Year Report4.1.2026 16:00:00 CET | Press release

Sinovac Biotech Ltd. (NASDAQ: SVA) (“SINOVAC” or the “Company”), a leading provider of biopharmaceutical products in China, today announced that it has received a notification letter dated January 2, 2026 (the “Notification Letter”) from Nasdaq Listing Qualifications (“Nasdaq”), stating that the Company was not in compliance with Nasdaq’s Listing Rule 5250(c)(2) since the Company did not timely file a Form 6-K containing an interim balance sheet and income statement as of the end of its second quarter of year 2025. As previously disclosed, the Company received a delisting determination letter (the “Staff Determination”) from Nasdaq in November 2025. The Company requested a hearing before the Nasdaq Hearings Panel to appeal the Staff Determination on November 19, 2025. Nasdaq has informed the Company that the Nasdaq Hearings Panel will also consider the matter addressed in the Notification Letter at a hearing scheduled for January 8, 2026 at which the Company has been invited to present

In our pressroom you can read all our latest releases, find our press contacts, images, documents and other relevant information about us.

Visit our pressroom
World GlobeA line styled icon from Orion Icon Library.HiddenA line styled icon from Orion Icon Library.Eye