MASIMO
6.9.2021 08:02:13 CEST | Business Wire | Press release
Masimo (NASDAQ: MASI) announced today the findings of a prospective, blinded observational study published in Annals of Intensive Care in which Dr. Jean-Baptiste Lascarrou and colleagues at the Centre Hospitalier Universitaire in Nantes, France evaluated the ability of Masimo ORi™ to predict mild hypoxemia during endotracheal intubation (ETI) in ICU patients.1 They concluded that the time between decrease in ORi and subsequent decrease in oxygen saturation (SpO2 ) “may allow preventive action,” and that a higher ORi value during preoxygenation was “independently protective against hypoxemia.”
This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20210905005031/en/
ORi, available outside the U.S., is a noninvasive and continuous trending index that extends oxygen monitoring on patients on supplemental oxygen. Enabled by the multi-wavelength rainbow® Pulse CO-Oximetry platform, ORi is provided alongside oxygen saturation (SpO2 ) measured by clinically proven Masimo SET® pulse oximetry.
Noting the importance of optimizing preoxygenation in patients needing ETI, the researchers sought to evaluate whether ORi could provide early warning of impending hypoxemia during the procedure, because ORi “supplies information beyond the range explored by SpO2. ” Of the 51 patients who met the inclusion criteria, ORi (alongside SpO2 ) was monitored using Masimo Radical-7® Pulse CO-Oximeters® and rainbow® fingertip sensors when preoxygenation began. Values were recorded every two seconds, and attending clinicians were not aware of these values. The primary endpoint measured was the time between ORi decreasing below 0.4 and the onset of mild hypoxemia (defined as SpO2 < 97%). Secondarily, the investigators evaluated whether a decline in ORi during preoxygenation predicted the occurrence of mild hypoxemia during ETI.
Analyzing areas under the ROC curve, the researchers found that ORi during preoxygenation predicted SpO2 < 97% during intubation (0.73; 95% confidence interval of 0.58 – 0.88). By contrast, SpO2 at the end of preoxygenation was “poorly predictive” (0.54; 95% CI 0.40 – 0.67). Using univariate analysis, they found that a higher ORi value during preoxygenation was associated with a less frequent occurrence of SpO2 < 97% (odds ratio of 0.09; 95% CI 0.01 – 0.69, p = 0.0199) and that “the highest ORi value during preoxygenation remained significantly associated with a lower risk of SpO2 < 97% during ETI, after adjustment for ETI duration and BMI (odds ratio of 0.76; 95% CI 0.61 – 0.95, p = 0.0141).”
The researchers concluded, “The median time between the ORi decrease below 0.4 and the SpO2 decrease below 97% during the apneic period was 81 seconds [34–146]. A higher ORi during preoxygenation was independently associated with a lower risk of mild hypoxemia (SpO2 < 97%).”
The researchers noted that the median 81 seconds of forewarning “may allow immediate intubation, early face-mask ventilation, insertion of a supraglottic device, or a call for help in the event of intubation difficulties.” In addition, they noted that “ORi monitoring can help identify patients who do not increase their oxygen reserve despite preoxygenation and are therefore at [increased] risk of desaturation during ETI. These patients may benefit from a longer preoxygenation period and/or a change in device.” The authors further noted that “an ORi decline might lead to the detection of a fault in the preoxygenation technique such as an insufficient oxygen flow rate or major leaks.”
As a study limitation, the authors noted that their findings cannot be generalized to ICU patients who did not meet the inclusion criteria, as those patient cohorts remain to be evaluated. The inclusion criteria for this study were ICU admission with a need for ETI and an SpO2 /FiO2 ratio above 214. The SpO2 /FiO2 ratio was measured during noninvasive ventilation or high-flow oxygen therapy; for conventional oxygen therapy, the fraction of inspired oxygen (FiO2 ) was calculated as FiO2 = 0.21 + O2 [rate in L/min] x 0.03.
ORi has not received FDA 510(k) clearance and is not available for sale in the United States.
@Masimo | #Masimo
About Masimo
Masimo (NASDAQ: MASI) is a global medical technology company that develops and produces a wide array of industry-leading monitoring technologies, including innovative measurements, sensors, patient monitors, and automation and connectivity solutions. Our mission is to improve patient outcomes, reduce the cost of care, and take noninvasive monitoring to new sites and applications. Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry, introduced in 1995, has been shown in over 100 independent and objective studies to outperform other pulse oximetry technologies.2 Masimo SET® has also been shown to help clinicians reduce severe retinopathy of prematurity in neonates,3 improve CCHD screening in newborns,4 and, when used for continuous monitoring with Masimo Patient SafetyNet™ in post-surgical wards, reduce rapid response team activations, ICU transfers, and costs.5-8 Masimo SET® is estimated to be used on more than 200 million patients in leading hospitals and other healthcare settings around the world,9 and is the primary pulse oximetry at 9 of the top 10 hospitals as ranked in the 2021-22 U.S. News and World Report Best Hospitals Honor Roll.10 Masimo continues to refine SET® and in 2018, announced that SpO2 accuracy on RD SET® sensors during conditions of motion has been significantly improved, providing clinicians with even greater confidence that the SpO2 values they rely on accurately reflect a patient’s physiological status. In 2005, Masimo introduced rainbow® Pulse CO-Oximetry technology, allowing noninvasive and continuous monitoring of blood constituents that previously could only be measured invasively, including total hemoglobin (SpHb® ), oxygen content (SpOC™), carboxyhemoglobin (SpCO® ), methemoglobin (SpMet® ), Pleth Variability Index (PVi® ), RPVi™ (rainbow® PVi), and Oxygen Reserve Index (ORi™). In 2013, Masimo introduced the Root® Patient Monitoring and Connectivity Platform, built from the ground up to be as flexible and expandable as possible to facilitate the addition of other Masimo and third-party monitoring technologies; key Masimo additions include Next Generation SedLine® Brain Function Monitoring, O3® Regional Oximetry, and ISA™ Capnography with NomoLine® sampling lines. Masimo’s family of continuous and spot-check monitoring Pulse CO-Oximeters® includes devices designed for use in a variety of clinical and non-clinical scenarios, including tetherless, wearable technology, such as Radius-7® and Radius PPG™, portable devices like Rad-67® , fingertip pulse oximeters like MightySat® Rx, and devices available for use both in the hospital and at home, such as Rad-97® . Masimo hospital automation and connectivity solutions are centered around the Masimo Hospital Automation™ platform, and include Iris® Gateway, iSirona™, Patient SafetyNet, Replica™, Halo ION™, UniView® , UniView :60™, and Masimo SafetyNet™. Additional information about Masimo and its products may be found at www.masimo.com . Published clinical studies on Masimo products can be found at www.masimo.com/evidence/featured-studies/feature/ .
ORi and RPVi have not received FDA 510(k) clearance and are not available for sale in the United States. The use of the trademark Patient SafetyNet is under license from University HealthSystem Consortium.
References
- Hille H, Le Thuaut A, Canet E, Lemarie J, Crosby L, Ottavy G, Garret C, Martin M, Seguin A, Lamouche-Wilquin P Morin J, Zambon O, Miaihle AF, Reignier J, Lascarrou JB. Oxygen reserve index for noninvasive early hypoxemia detection during endotracheal intubation in intensive care: the prospective observational NESOI study. Ann. Intensive Care . 2021 11:112. DOI: 10.1186/s13613-021-00903-8.
- Published clinical studies on pulse oximetry and the benefits of Masimo SET® can be found on our website at http://www.masimo.com . Comparative studies include independent and objective studies which are comprised of abstracts presented at scientific meetings and peer-reviewed journal articles.
- Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
- de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;Jan 8;338.
- Taenzer A et al. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology . 2010:112(2):282-287.
- Taenzer A et al. Postoperative Monitoring – The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter . Spring-Summer 2012.
- McGrath S et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation. The Joint Commission Journal on Quality and Patient Safety . 2016 Jul;42(7):293-302.
- McGrath S et al. Inpatient Respiratory Arrest Associated With Sedative and Analgesic Medications: Impact of Continuous Monitoring on Patient Mortality and Severe Morbidity. J Patient Saf. 2020 14 Mar. DOI: 10.1097/PTS.0000000000000696.
- Estimate: Masimo data on file.
- http://health.usnews.com/health-care/best-hospitals/articles/best-hospitals-honor-roll-and-overview .
Forward-Looking Statements
This press release includes forward-looking statements as defined in Section 27A of the Securities Act of 1933 and Section 21E of the Securities Exchange Act of 1934, in connection with the Private Securities Litigation Reform Act of 1995. These forward-looking statements include, among others, statements regarding the potential effectiveness of Masimo ORi™. These forward-looking statements are based on current expectations about future events affecting us and are subject to risks and uncertainties, all of which are difficult to predict and many of which are beyond our control and could cause our actual results to differ materially and adversely from those expressed in our forward-looking statements as a result of various risk factors, including, but not limited to: risks related to our assumptions regarding the repeatability of clinical results; risks that findings in the new study on Masimo ORi's ability to predict hypoxemia during ETI cannot be generalized; risks that researchers’ conclusion on the practical applications of Masimo ORi’s forewarning ability may not be accurate; risks related to our belief that Masimo's unique noninvasive measurement technologies, including Masimo ORi, contribute to positive clinical outcomes and patient safety; risks related to our belief that Masimo noninvasive medical breakthroughs provide cost-effective solutions and unique advantages; risks related to COVID-19; as well as other factors discussed in the "Risk Factors" section of our most recent reports filed with the Securities and Exchange Commission ("SEC"), which may be obtained for free at the SEC's website at www.sec.gov . Although we believe that the expectations reflected in our forward-looking statements are reasonable, we do not know whether our expectations will prove correct. All forward-looking statements included in this press release are expressly qualified in their entirety by the foregoing cautionary statements. You are cautioned not to place undue reliance on these forward-looking statements, which speak only as of today's date. We do not undertake any obligation to update, amend or clarify these statements or the "Risk Factors" contained in our most recent reports filed with the SEC, whether as a result of new information, future events or otherwise, except as may be required under the applicable securities laws.
View source version on businesswire.com: https://www.businesswire.com/news/home/20210905005031/en/
Link:
About Business Wire
Subscribe to releases from Business Wire
Subscribe to all the latest releases from Business Wire by registering your e-mail address below. You can unsubscribe at any time.
Latest releases from Business Wire
Visa Opens the Door to AI-Driven Shopping for Businesses Worldwide8.4.2026 18:00:00 CEST | Press release
Part of the Visa Intelligent Commerce portfolio, Intelligent Commerce Connect will enable more ways for agents to pay and merchants to accept agentic transactions in a single integrationCurrently in pilot with select partners including Aldar, AWS, Diddo, Highnote, Mesh, Payabli, Sumvin, and rolling out to more partners this year Visa Inc. (NYSE: V) today unveiled Intelligent Commerce Connect, a new solution that makes it easier for businesses to connect to and participate in AI-powered commerce. Intelligent Commerce Connect acts as a network, protocol, and token vault-agnostic ‘on ramp’ to agentic commerce for agent builders, merchants, and enablers. As consumers increasingly rely on AI agents to make purchases, businesses – whether they are building agents, selling to them, or processing transactions – need a simple way to get started. Intelligent Commerce Connect, part of the Visa Intelligent Commerce portfolio, meets that need. Through a single integration via the Visa Acceptance Pl
Sumitomo Corporation, SMBC Aviation Capital, Apollo and Brookfield Complete the Acquisition of Air Lease Corporation8.4.2026 15:13:00 CEST | Press release
Sumitomo Corporation, SMBC Aviation Capital, Apollo-managed funds (“Apollo”) and Brookfield today announced that they have completed the previously announced acquisition of Air Lease Corporation (“Air Lease”) and have renamed the business Sumisho Air Lease Corporation (“Sumisho Air Lease”). This transformational transaction improves the financial position of the business with long term support and aviation expertise from co-investors Sumitomo Corporation, SMBC Aviation Capital, Apollo and Brookfield. Sumisho Air Lease’s strong foundation as an established aircraft lessor, supported by SMBC Aviation Capital’s industry‑leading capabilities as servicer, creates a platform with the scale and financial strength needed to meet the fast‑changing and increasingly complex requirements of airline customers. Sumisho Air Lease will also benefit from the deep expertise and long-standing commitment that both Sumitomo Corporation and SMBC Aviation Capital bring to the global aviation leasing sector.
Sitetracker Launches Scout, an Agentic AI Platform Purpose-Built for Critical Infrastructure8.4.2026 15:00:00 CEST | Press release
Sitetracker, the leading Asset Lifecycle Management platform for critical infrastructure, today announced the launch of Scout, its new Agentic AI platform designed to help infrastructure owners, operators, and contractors gain deep insights and drive automation within their operations. This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20260408923336/en/ Scout, ready for real work As your AI analyst and agent, Scout is ready to work on day 1. Scout provides clarity when decisions are forming and momentum when action is required. It surfaces risk, synthesizes information, and helps accelerate execution by connecting data and driving action. Scout creates operational intelligence and turns it into action all in a secure environment that protects data sovereignty. “Our customers are looking to create compounding competitive advantages,” said Giuseppe Incitti, Chief Executive Officer of Sitetracker. “Scout delivers by providing easy t
Westinghouse Hosts Annual VVER Fuel Forum with Customers8.4.2026 15:00:00 CEST | Press release
Westinghouse currently has fuel supply contracts with all the European VVER operators Westinghouse and MVM Paks Nuclear Power Plant (NPP) recently co-hosted the VVER Fuel Forum in Budapest to share insights and plans for the continued deployment of VVER-1000 and VVER-440 fuel in operating reactors. This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20260408646373/en/ Participants to the VVER Fuel Forum Péter János Horváth, CEO of MVM Paks, welcomed all the participants, highlighting that Hungary is ending two decades of single supplier fuel dependency thanks to the agreement recently signed with Westinghouse to supply the VVER-440 NOVA E-6 fuel design. Six customers presented the progress made and positive outcomes achieved in the past years with the introduction of Westinghouse fuel into mixed cores with resident fuel in their reactors: Energoatom has extensive experience with Westinghouse VVER-440 and VVER-1000 fuel, currently u
Virica Biotech and FUJIFILM Biosciences Collaborate Under the Canada–Japan Co‑Innovation Program to Advance AAV Production Enhancers8.4.2026 15:00:00 CEST | Press release
Efficient production of Adeno-Associated Virus (AAV) vectors at scale for in vivo gene therapies remains a key bottleneck for broad patient access and sustainable manufacturing costs.Virica and FUJIFILM Biosciences will co-develop an off-the-shelf enhancer–media solution to boost AAV yields and process robustness in FUJIFILM Biosciences BalanCD® HEK293 system. Virica Biotech (“Virica”), a cell enhancer company specializing in Viral Sensitizers (VSE™) for viral vector manufacturing, today announced it is receiving advisory services and funding from the National Research Council of Canada Industrial Research Assistance Program (NRC IRAP), under the Canada–Japan Corporate Co-Innovation Program for a collaboration with FUJIFILM Biosciences. The collaboration will focus on optimizing a VSE™ formulation for FUJIFILM Biosciences BalanCD HEK293 media to support academic and commercial AAV producers globally. AAV vectors are a cornerstone of in vivo gene delivery for gene therapies, but they re
In our pressroom you can read all our latest releases, find our press contacts, images, documents and other relevant information about us.
Visit our pressroom
