Business Wire

MASIMO

Share
New Study Investigates the Ability of Masimo ORi™ to Provide Early Warning of Hypoxemia During Endotracheal Intubation in ICU Patients

Masimo (NASDAQ: MASI) announced today the findings of a prospective, blinded observational study published in Annals of Intensive Care in which Dr. Jean-Baptiste Lascarrou and colleagues at the Centre Hospitalier Universitaire in Nantes, France evaluated the ability of Masimo ORi™ to predict mild hypoxemia during endotracheal intubation (ETI) in ICU patients.1 They concluded that the time between decrease in ORi and subsequent decrease in oxygen saturation (SpO2 ) “may allow preventive action,” and that a higher ORi value during preoxygenation was “independently protective against hypoxemia.”

This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20210905005031/en/

ORi, available outside the U.S., is a noninvasive and continuous trending index that extends oxygen monitoring on patients on supplemental oxygen. Enabled by the multi-wavelength rainbow® Pulse CO-Oximetry platform, ORi is provided alongside oxygen saturation (SpO2 ) measured by clinically proven Masimo SET® pulse oximetry.

Noting the importance of optimizing preoxygenation in patients needing ETI, the researchers sought to evaluate whether ORi could provide early warning of impending hypoxemia during the procedure, because ORi “supplies information beyond the range explored by SpO2. ” Of the 51 patients who met the inclusion criteria, ORi (alongside SpO2 ) was monitored using Masimo Radical-7® Pulse CO-Oximeters® and rainbow® fingertip sensors when preoxygenation began. Values were recorded every two seconds, and attending clinicians were not aware of these values. The primary endpoint measured was the time between ORi decreasing below 0.4 and the onset of mild hypoxemia (defined as SpO2 < 97%). Secondarily, the investigators evaluated whether a decline in ORi during preoxygenation predicted the occurrence of mild hypoxemia during ETI.

Analyzing areas under the ROC curve, the researchers found that ORi during preoxygenation predicted SpO2 < 97% during intubation (0.73; 95% confidence interval of 0.58 – 0.88). By contrast, SpO2 at the end of preoxygenation was “poorly predictive” (0.54; 95% CI 0.40 – 0.67). Using univariate analysis, they found that a higher ORi value during preoxygenation was associated with a less frequent occurrence of SpO2 < 97% (odds ratio of 0.09; 95% CI 0.01 – 0.69, p = 0.0199) and that “the highest ORi value during preoxygenation remained significantly associated with a lower risk of SpO2 < 97% during ETI, after adjustment for ETI duration and BMI (odds ratio of 0.76; 95% CI 0.61 – 0.95, p = 0.0141).”

The researchers concluded, “The median time between the ORi decrease below 0.4 and the SpO2 decrease below 97% during the apneic period was 81 seconds [34–146]. A higher ORi during preoxygenation was independently associated with a lower risk of mild hypoxemia (SpO2 < 97%).”

The researchers noted that the median 81 seconds of forewarning “may allow immediate intubation, early face-mask ventilation, insertion of a supraglottic device, or a call for help in the event of intubation difficulties.” In addition, they noted that “ORi monitoring can help identify patients who do not increase their oxygen reserve despite preoxygenation and are therefore at [increased] risk of desaturation during ETI. These patients may benefit from a longer preoxygenation period and/or a change in device.” The authors further noted that “an ORi decline might lead to the detection of a fault in the preoxygenation technique such as an insufficient oxygen flow rate or major leaks.”

As a study limitation, the authors noted that their findings cannot be generalized to ICU patients who did not meet the inclusion criteria, as those patient cohorts remain to be evaluated. The inclusion criteria for this study were ICU admission with a need for ETI and an SpO2 /FiO2 ratio above 214. The SpO2 /FiO2 ratio was measured during noninvasive ventilation or high-flow oxygen therapy; for conventional oxygen therapy, the fraction of inspired oxygen (FiO2 ) was calculated as FiO2 = 0.21 + O2 [rate in L/min] x 0.03.

ORi has not received FDA 510(k) clearance and is not available for sale in the United States.

@Masimo | #Masimo

About Masimo

Masimo (NASDAQ: MASI) is a global medical technology company that develops and produces a wide array of industry-leading monitoring technologies, including innovative measurements, sensors, patient monitors, and automation and connectivity solutions. Our mission is to improve patient outcomes, reduce the cost of care, and take noninvasive monitoring to new sites and applications. Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry, introduced in 1995, has been shown in over 100 independent and objective studies to outperform other pulse oximetry technologies.2 Masimo SET® has also been shown to help clinicians reduce severe retinopathy of prematurity in neonates,3 improve CCHD screening in newborns,4 and, when used for continuous monitoring with Masimo Patient SafetyNet™ in post-surgical wards, reduce rapid response team activations, ICU transfers, and costs.5-8 Masimo SET® is estimated to be used on more than 200 million patients in leading hospitals and other healthcare settings around the world,9 and is the primary pulse oximetry at 9 of the top 10 hospitals as ranked in the 2021-22 U.S. News and World Report Best Hospitals Honor Roll.10 Masimo continues to refine SET® and in 2018, announced that SpO2 accuracy on RD SET® sensors during conditions of motion has been significantly improved, providing clinicians with even greater confidence that the SpO2 values they rely on accurately reflect a patient’s physiological status. In 2005, Masimo introduced rainbow® Pulse CO-Oximetry technology, allowing noninvasive and continuous monitoring of blood constituents that previously could only be measured invasively, including total hemoglobin (SpHb® ), oxygen content (SpOC™), carboxyhemoglobin (SpCO® ), methemoglobin (SpMet® ), Pleth Variability Index (PVi® ), RPVi™ (rainbow® PVi), and Oxygen Reserve Index (ORi™). In 2013, Masimo introduced the Root® Patient Monitoring and Connectivity Platform, built from the ground up to be as flexible and expandable as possible to facilitate the addition of other Masimo and third-party monitoring technologies; key Masimo additions include Next Generation SedLine® Brain Function Monitoring, O3® Regional Oximetry, and ISA™ Capnography with NomoLine® sampling lines. Masimo’s family of continuous and spot-check monitoring Pulse CO-Oximeters® includes devices designed for use in a variety of clinical and non-clinical scenarios, including tetherless, wearable technology, such as Radius-7® and Radius PPG™, portable devices like Rad-67® , fingertip pulse oximeters like MightySat® Rx, and devices available for use both in the hospital and at home, such as Rad-97® . Masimo hospital automation and connectivity solutions are centered around the Masimo Hospital Automation™ platform, and include Iris® Gateway, iSirona™, Patient SafetyNet, Replica™, Halo ION™, UniView® , UniView :60™, and Masimo SafetyNet™. Additional information about Masimo and its products may be found at www.masimo.com . Published clinical studies on Masimo products can be found at www.masimo.com/evidence/featured-studies/feature/ .

ORi and RPVi have not received FDA 510(k) clearance and are not available for sale in the United States. The use of the trademark Patient SafetyNet is under license from University HealthSystem Consortium.

References

  1. Hille H, Le Thuaut A, Canet E, Lemarie J, Crosby L, Ottavy G, Garret C, Martin M, Seguin A, Lamouche-Wilquin P Morin J, Zambon O, Miaihle AF, Reignier J, Lascarrou JB. Oxygen reserve index for noninvasive early hypoxemia detection during endotracheal intubation in intensive care: the prospective observational NESOI study. Ann. Intensive Care . 2021 11:112. DOI: 10.1186/s13613-021-00903-8.
  2. Published clinical studies on pulse oximetry and the benefits of Masimo SET® can be found on our website at http://www.masimo.com . Comparative studies include independent and objective studies which are comprised of abstracts presented at scientific meetings and peer-reviewed journal articles.
  3. Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
  4. de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;Jan 8;338.
  5. Taenzer A et al. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology . 2010:112(2):282-287.
  6. Taenzer A et al. Postoperative Monitoring – The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter . Spring-Summer 2012.
  7. McGrath S et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation. The Joint Commission Journal on Quality and Patient Safety . 2016 Jul;42(7):293-302.
  8. McGrath S et al. Inpatient Respiratory Arrest Associated With Sedative and Analgesic Medications: Impact of Continuous Monitoring on Patient Mortality and Severe Morbidity. J Patient Saf. 2020 14 Mar. DOI: 10.1097/PTS.0000000000000696.
  9. Estimate: Masimo data on file.
  10. http://health.usnews.com/health-care/best-hospitals/articles/best-hospitals-honor-roll-and-overview .

Forward-Looking Statements

This press release includes forward-looking statements as defined in Section 27A of the Securities Act of 1933 and Section 21E of the Securities Exchange Act of 1934, in connection with the Private Securities Litigation Reform Act of 1995. These forward-looking statements include, among others, statements regarding the potential effectiveness of Masimo ORi™. These forward-looking statements are based on current expectations about future events affecting us and are subject to risks and uncertainties, all of which are difficult to predict and many of which are beyond our control and could cause our actual results to differ materially and adversely from those expressed in our forward-looking statements as a result of various risk factors, including, but not limited to: risks related to our assumptions regarding the repeatability of clinical results; risks that findings in the new study on Masimo ORi's ability to predict hypoxemia during ETI cannot be generalized; risks that researchers’ conclusion on the practical applications of Masimo ORi’s forewarning ability may not be accurate; risks related to our belief that Masimo's unique noninvasive measurement technologies, including Masimo ORi, contribute to positive clinical outcomes and patient safety; risks related to our belief that Masimo noninvasive medical breakthroughs provide cost-effective solutions and unique advantages; risks related to COVID-19; as well as other factors discussed in the "Risk Factors" section of our most recent reports filed with the Securities and Exchange Commission ("SEC"), which may be obtained for free at the SEC's website at www.sec.gov . Although we believe that the expectations reflected in our forward-looking statements are reasonable, we do not know whether our expectations will prove correct. All forward-looking statements included in this press release are expressly qualified in their entirety by the foregoing cautionary statements. You are cautioned not to place undue reliance on these forward-looking statements, which speak only as of today's date. We do not undertake any obligation to update, amend or clarify these statements or the "Risk Factors" contained in our most recent reports filed with the SEC, whether as a result of new information, future events or otherwise, except as may be required under the applicable securities laws.

Link:

ClickThru

About Business Wire

Business Wire
Business Wire
101 California Street, 20th Floor
CA 94111 San Francisco

http://businesswire.com

Subscribe to releases from Business Wire

Subscribe to all the latest releases from Business Wire by registering your e-mail address below. You can unsubscribe at any time.

Latest releases from Business Wire

Quectel Announces Industry First 5G-Advanced 3GPP R18 Automotive-Grade Cellular Module, Delivering Unmatched Performance and Reliability2.1.2026 18:00:00 CET | Press release

Quectel Wireless Solutions, an end-to-end global IoT solutions provider, today announces the launch of the world's first 5G-advanced (5G-A) automotive-grade cellular module, the AR588MA, establishing it as the industry's highest-performing and most reliable wireless communication product for vehicles. Based on MediaTek's latest-generation MT2739 platform, the AR588MA supports 5G-A communication technology and is the world's first to comply with the 3GPP R18 standard protocol. The module also features both NB-NTN and NR-NTN satellite communication capabilities, supports Dual SIM Dual Active (DSDA) technology, offering improved stability and reliability on cellular connections and includes intelligent driving scenario recognition. Designed in compliance with the AEC-Q104 Grade 2 automotive standard, it delivers faster, more stable connectivity and reliable security for in-vehicle communication and benefiting the on-roof applications like smart antenna for automotive with higher temperatu

Interactive Brokers’ Individual and Hedge Fund Clients Outperformed the S&P 500 on Average in 20252.1.2026 16:00:00 CET | Press release

Lower costs, global market access, and efficient execution contributed to stronger client outcomes. Interactive Brokers (Nasdaq: IBKR), an automated global electronic broker, today announced that its clients outperformed the S&P 500 Index in 2025, reflecting the benefits of cost efficiency, execution quality, and broad access to global markets. In 2025, Interactive Brokers’ individual clients achieved an average return of 19.20%, compared with the 17.9% return of the S&P 500 Index. During the same period, Interactive Brokers’ hedge fund clients achieved an average return of 28.91%, outperforming the index by approximately 11 percentage points. These results demonstrate how Interactive Brokers helps enhance client returns across the investment lifecycle. Global market access enables clients to allocate capital across various regions and asset classes, while lower trading and financing costs, along with efficient execution, help IBKR investors retain more of their returns over time. “Inv

Aeromexico Repeats as Most On-Time Global Airline; Qatar Airways Claims Platinum Award2.1.2026 11:00:00 CET | Press release

Virgin Atlantic wins new award as most improved airline for on-time performance Aeromexico maintained a 90.02% on-time performance to claim the world's most on-time global airline title for the second consecutive year, according to Cirium's 2025 On-Time Performance Review released today. The Mexican carrier becomes only the second airline to achieve consecutive global wins since Cirium launched the program in 2009, operating 188,859 flights across 23 countries while maintaining industry-leading schedule reliability. Aeromexico Holds Global Lead; Regional Champions Crowned Aeromexico secured the global airline title with 90.02% on-time performance, holding off strong competition from Saudia in second place with 86.53% and SAS with 86.09% in third. The margin between first and third place was 3.93 percentage points, reflecting the strong performance of Aeromexico in 2025. Regional winners included: North America: Delta Air Lines won for the fifth consecutive year with 80.90% on-time perf

Samsung Bioepis Begins Commercialization of BYOOVIZ®, Biosimilar to Lucentis (Ranibizumab), in Europe2.1.2026 08:00:00 CET | Press release

Samsung Bioepis completes full transfer of commercial rights from Biogen back to Samsung Bioepis for BYOOVIZ®BYOOVIZ becomes the fourth biosimilar directly commercialized by Samsung Bioepis in Europe, following EPYSQLI® (eculizumab), OBODENCE® (denosumab), and XBRYK® (denosumab)Pre-filled syringe (PFS) presentation to become available in Europe in the second quarter of 2026 Samsung Bioepis Co., Ltd. today announced that the company has begun direct commercialization of BYOOVIZ®, a biosimilar to Lucentis1 (ranibizumab), in Europe. Samsung Bioepis has been working to ensure seamless transfer of commercial rights from Biogen back to Samsung Bioepis, and BYOOVIZ will now be available as a Samsung Bioepis brand across multiple European countries. “This is a significant milestone for Samsung Bioepis as the company continues to strengthen its presence in Europe by expanding its portfolio of directly commercialized products. Leveraging the past three years of experience with EPYSQLI (eculizuma

Cessna Citation Ascend Enters Into Service, Redefining Performance and Cabin Experience in the Midsize Business Jet Market31.12.2025 15:00:00 CET | Press release

The Cessna Citation Ascend achieved a major milestone as the first retail customer took delivery of the midsize business jet on Tuesday, December 30, marking the aircraft’s entry into service. Announced in 2023 the aircraft boasts an entirely new cockpit, improved performance and a luxurious flat floor cabin. The Citation Ascend received type certification from the Federal Aviation Administration (FAA) in November 2025. This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20251231586042/en/ Cessna Citation Ascend enters into service, redefining performance and cabin experience in the midsize business jet market. (Photo credit: Textron Aviation) The Cessna Citation Ascend is designed and manufactured by Textron Aviation Inc., a Textron Inc. (NYSE: TXT) company. “The first Citation Ascend delivery underscores Textron Aviation’s commitment to redefining the midsize segment with an aircraft that blends innovation, efficiency and unmatch

In our pressroom you can read all our latest releases, find our press contacts, images, documents and other relevant information about us.

Visit our pressroom
World GlobeA line styled icon from Orion Icon Library.HiddenA line styled icon from Orion Icon Library.Eye