Masimo (NASDAQ: MASI) announced today the findings of a study published in the Turkish Journal of Medical Sciences in which Dr. Ayten Saracoglu and colleagues at the Marmara University Pendik Training and Research Hospital in Istanbul evaluated the ability of ORi to guide oxygenation by measuring its impact on hyperoxemia-mediated morbidity during one-lung ventilation (OLV) conducted as part of thoracic surgery.1 They concluded that ORi-guided oxygen titration “may reduce hospital stay and increase patient safety.”
This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20210613005039/en/
ORi, available outside the U.S. since 2014, is a noninvasive and continuous parameter intended to provide additional insight into a patient’s oxygen status under supplemental oxygen. Enabled by the multi-wavelength rainbow® Pulse CO-Oximetry platform, ORi is provided alongside oxygen saturation (SpO2 ) measured by clinically proven Masimo SET® pulse oximetry.
Noting that during OLV, a common technique for facilitating a wide variety of pulmonary procedures, 100% fraction of inspired oxygen (FiO2 ) supplemental oxygen administration is commonly used, which exposes patients to the possibility of hyperoxia-induced lung injury, the researchers sought to determine whether ORi could “protect patient from the harmful effects of hyperoxemia with a noninvasive probe during OLV.” They divided 103 patients with lung tumors (18-70 years of age, ASA I-III), enrolled between September 2018 and September 2019 and requiring OLV as part of elective thoracic surgery, into four groups as noted below:
Group |
Number
|
Duration of
|
Mean FiO2
|
1: Oxygen titration without ORi, low-flow anesthesia (1 L/min) |
25 |
67.6 ± 97.5 mins. |
71.6 ± 12.25% |
2: Oxygen titration without ORi, high-flow anesthesia (4 L/min) |
28 |
97.32 ± 99.7 mins. |
74.64 ± 16.66% |
3: Oxygen titration with ORi, low-flow anesthesia (1 L/min) |
25 |
39.2 ± 74.1 mins. |
62.8 ± 13.08% |
4: Oxygen titration with ORi, high-flow anesthesia (4 L/min) |
25 |
22.4 ± 49.4 mins. |
56.4 ± 11.5% |
During OLV, oxygen titration was performed without ORi for patients in groups 1 and 2, while groups 3 and 4 used ORi from Masimo Radical-7® Pulse CO-Oximeters® and rainbow® sensors. For all 4 groups, SpO2 and partial pressure of arterial oxygen (PaO2 ) were routinely measured while FiO2 was routinely administered at 50% after induction, rising to 60% when the OLV was applied, and increasing to 70%-100% as necessary.
The researchers found that ORi monitoring was associated with significantly shorter duration of OLV with FiO2 > 60%, with significantly lower mean FiO2 values during OLV (as shown in the table above), and with lower recorded PaO2 values. They also found that the duration of FiO2 > 80% during OLV was strongly correlated with longer hospital stays (p < 0.001).
The observation that mean FiO2 values were found to be significantly lower in the ORi groups (3 and 4), compared to the groups without ORi (1 and 2), led the researchers to hypothesize that “the risk of hyperoxia will be lower in patients undergoing ORi monitor[ing].” The researchers noted, “ORi cannot replace arterial blood gas analysis; however, it is useful to assess oxygenation. In groups without ORi monitors, the FiO2 was significantly higher than 80%. Moreover, in our study, it was revealed that these patients had a longer hospital stay.”
There was no significant difference in ORi values between the low-flow (group 3) and high-flow (group 4) cohorts.
The researchers concluded, “The adjustment of ORi with peripheral oxygen saturation and blood gas analysis demonstrated that hyperoxemia could be prevented during OLV in patients under low flow or high flow anesthesia. We concluded that ORi-guided thoracic anesthesia may reduce hospital stay and increase patient safety.”
ORi has not yet received FDA clearance and is not available in the United States.
@Masimo | #Masimo
About Masimo
Masimo (NASDAQ: MASI) is a global medical technology company that develops and produces a wide array of industry-leading monitoring technologies, including innovative measurements, sensors, patient monitors, and automation and connectivity solutions. Our mission is to improve patient outcomes, reduce the cost of care, and take noninvasive monitoring to new sites and applications. Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry, introduced in 1995, has been shown in over 100 independent and objective studies to outperform other pulse oximetry technologies.2 Masimo SET® has also been shown to help clinicians reduce severe retinopathy of prematurity in neonates,3 improve CCHD screening in newborns,4 and, when used for continuous monitoring with Masimo Patient SafetyNet™ in post-surgical wards, reduce rapid response team activations, ICU transfers, and costs.5-8 Masimo SET® is estimated to be used on more than 200 million patients in leading hospitals and other healthcare settings around the world,9 and is the primary pulse oximetry at 9 of the top 10 hospitals according to the 2020-21 U.S. News and World Report Best Hospitals Honor Roll.10 Masimo continues to refine SET® and in 2018, announced that SpO2 accuracy on RD SET® sensors during conditions of motion has been significantly improved, providing clinicians with even greater confidence that the SpO2 values they rely on accurately reflect a patient’s physiological status. In 2005, Masimo introduced rainbow® Pulse CO-Oximetry technology, allowing noninvasive and continuous monitoring of blood constituents that previously could only be measured invasively, including total hemoglobin (SpHb® ), oxygen content (SpOC™), carboxyhemoglobin (SpCO® ), methemoglobin (SpMet® ), Pleth Variability Index (PVi® ), RPVi™ (rainbow® PVi), and Oxygen Reserve Index (ORi™). In 2013, Masimo introduced the Root® Patient Monitoring and Connectivity Platform, built from the ground up to be as flexible and expandable as possible to facilitate the addition of other Masimo and third-party monitoring technologies; key Masimo additions include Next Generation SedLine® Brain Function Monitoring, O3® Regional Oximetry, and ISA™ Capnography with NomoLine® sampling lines. Masimo’s family of continuous and spot-check monitoring Pulse CO-Oximeters® includes devices designed for use in a variety of clinical and non-clinical scenarios, including tetherless, wearable technology, such as Radius-7® and Radius PPG™, portable devices like Rad-67® , fingertip pulse oximeters like MightySat® Rx, and devices available for use both in the hospital and at home, such as Rad-97® . Masimo hospital automation and connectivity solutions are centered around the Masimo Hospital Automation™ platform, and include Iris® Gateway, iSirona™, Patient SafetyNet, Replica™, Halo ION™, UniView® , UniView :60™, and Masimo SafetyNet™. Additional information about Masimo and its products may be found at www.masimo.com . Published clinical studies on Masimo products can be found at www.masimo.com/evidence/featured-studies/feature/ .
ORi and RPVi have not received FDA 510(k) clearance and are not available for sale in the United States. The use of the trademark Patient SafetyNet is under license from University HealthSystem Consortium.
References
- Saracoglu A, Yamansavci Şirzai E, Yildizeli B, Yüksel M, Aykaç ZZ. Oxygen Reserve Index Guided Oxygen Titration in One Lung Ventilation with Low Fresh Gas Glow. Turkish Journal of Medical Sciences . 2021 May. DOI: 10.3906/sag-2009-149.
- Published clinical studies on pulse oximetry and the benefits of Masimo SET® can be found on our website at http://www.masimo.com . Comparative studies include independent and objective studies which are comprised of abstracts presented at scientific meetings and peer-reviewed journal articles.
- Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
- de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;Jan 8;338.
- Taenzer A et al. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology . 2010:112(2):282-287.
- Taenzer A et al. Postoperative Monitoring – The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter . Spring-Summer 2012.
- McGrath S et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation. The Joint Commission Journal on Quality and Patient Safety . 2016 Jul;42(7):293-302.
- McGrath S et al. Inpatient Respiratory Arrest Associated With Sedative and Analgesic Medications: Impact of Continuous Monitoring on Patient Mortality and Severe Morbidity. J Patient Saf. 2020 14 Mar. DOI: 10.1097/PTS.0000000000000696.
- Estimate: Masimo data on file.
- http://health.usnews.com/health-care/best-hospitals/articles/best-hospitals-honor-roll-and-overview .
Forward-Looking Statements
This press release includes forward-looking statements as defined in Section 27A of the Securities Act of 1933 and Section 21E of the Securities Exchange Act of 1934, in connection with the Private Securities Litigation Reform Act of 1995. These forward-looking statements include, among others, statements regarding the potential effectiveness of Masimo ORi™. These forward-looking statements are based on current expectations about future events affecting us and are subject to risks and uncertainties, all of which are difficult to predict and many of which are beyond our control and could cause our actual results to differ materially and adversely from those expressed in our forward-looking statements as a result of various risk factors, including, but not limited to: risks related to our assumptions regarding the repeatability of clinical results; risks related to our belief that Masimo's unique noninvasive measurement technologies, including Masimo ORi, contribute to positive clinical outcomes and patient safety; risks related to our belief that Masimo noninvasive medical breakthroughs provide cost-effective solutions and unique advantages; risks related to COVID-19; as well as other factors discussed in the "Risk Factors" section of our most recent reports filed with the Securities and Exchange Commission ("SEC"), which may be obtained for free at the SEC's website at www.sec.gov . Although we believe that the expectations reflected in our forward-looking statements are reasonable, we do not know whether our expectations will prove correct. All forward-looking statements included in this press release are expressly qualified in their entirety by the foregoing cautionary statements. You are cautioned not to place undue reliance on these forward-looking statements, which speak only as of today's date. We do not undertake any obligation to update, amend or clarify these statements or the "Risk Factors" contained in our most recent reports filed with the SEC, whether as a result of new information, future events or otherwise, except as may be required under the applicable securities laws.
View source version on businesswire.com: https://www.businesswire.com/news/home/20210613005039/en/
Link:
About Business Wire
Subscribe to releases from Business Wire
Subscribe to all the latest releases from Business Wire by registering your e-mail address below. You can unsubscribe at any time.
Latest releases from Business Wire
Allianz Announces Excellent Performance and Is Fully on Track for Full-year Ambitions7.8.2025 07:13:00 CEST | Press release
2Q 2025 This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20250806235547/en/ Oliver Bäte, Chief Executive Officer of Allianz SE Allianz achieves strong growth and record operating profitTotal business volume rises 8.01 percent to 44.5 billion euros, supported by good growth across all segments Operating profit increases 12.2 percent and reaches a record level of 4.4 billion euros, with particular strong contribution from the Property-Casualty segment Shareholders’ core net income advances by 17.3 percent and reaches 3.0 billion euros. Adjusted for the 0.3 billion euros disposal gain on the UniCredit Joint Venture, shareholders’ core net income increases 7.1 percent 6M 2025 Excellent performance across our businesses and record operating profitTotal business volume grows 10.1 1 percent and reaches 98.5 billion euros, with contributions from all segments Operating profit increases 9.3 percent to 8.6 billion euros, our highest half-
New pulp mill boosts Suzano's sales and revenue in the second quarter of 20257.8.2025 04:17:00 CEST | Press release
Suzano, the world’s largest pulp producer, announces its results for the second quarter of 2025 (2Q25), reporting sales of 3.7 million tonnes of pulp and paper. Sales increased 28% over the same period in 2024 (2Q24), mainly reflecting the strong operational contribution of the new Ribas do Rio Pardo pulp mill, whose production started in July 2024. Net revenue in the quarter totaled R$13.3 billion, a 16% increase compared to 2Q24. The expansion of pulp production capacity in Brazil, combined with the positive contribution to paper sales from the mills recently acquired in the United States and favorable FX rates, mitigated the impact on net revenue of lower pulp prices in the global market compared to 2Q24. As a result, Suzano's adjusted EBITDA reached R$6.1 billion and operating cash generation totaled R$4.1 billion. Net profit totaled R$5.0 billion positively impacted by the accounting impact of US dollar denominated debt and hedging operations translating into Brazilian Real. Beto
Graanul - Update on the Consent Solicitation and Scheme Solicitation6.8.2025 22:22:00 CEST | Press release
Graanul: Update on the Consent Solicitation and Scheme Solicitation relating to: €250,000,000 Floating Rate Sustainability-Linked Senior Secured Notes due 2026 (Regulation S Notes: ISIN Number XS2397354015 / Common Code 239735401 Rule 144A Notes: ISIN Number XS2397354288 / Common Code 239735428) (the “Existing Floating Rate Notes”) and €380,000,000 4.625% Sustainability-Linked Senior Secured Notes due 2026 (Regulation S Notes: ISIN Number XS2397354528 / Common Code 239735452 Rule 144A Notes: ISIN Number: XS2397355095 / Common Code 239735509) (the “Existing Fixed Rate Notes” and together with the Existing Floating Rate Notes, the “Existing Notes”) of Cullinan Holdco SCSp a special limited partnership (société en commandite spéciale) established under the laws of Luxembourg, having its registered office at 2, avenue Charles de Gaulle, L-1653, registered with the Luxembourg Register of Commerce and Companies under number B-256979 (the “Issuer” and together with its subsidiaries, “Graanul”
Statement by Aviator LLC6.8.2025 16:18:00 CEST | Press release
Company successfully initiates proceedings following Georgian court victories; UK injunction preserves status quo pending trial Aviator LLC today issued a statement clarifying the nature and scope of a recent UK court ruling following public statements made by SPRIBE OU regarding interim injunction proceedings. According to Nikoloz Gogilidze, legal representative for Aviator LLC, the recent court order was an interim injunction with limited scope and commercial impact. Gogilidze highlights the key points of the proceedings, which appear to have been mischaracterized in some media reports. Nature of the Court Order: The ruling represents an interim injunction granted at a preliminary procedural stage, not a final determination on the merits of the underlying dispute. Such orders are designed to maintain the status quo pending full trial proceedings. Commercial Impact: The injunction has no practical effect as neither Aviator LLC nor its IP rights licensee had any existing plans to enter
Lenovo Brings Its Biggest-Ever Global Tech World Event to CES 2026 With an Immersive Experience at Sphere in Las Vegas6.8.2025 15:05:00 CEST | Press release
Lenovo Chairman and CEO Yuanqing Yang to deliver CES keynote on smarter AI for all at iconic venue, showcasing innovations with FIFA, Formula 1®, and a host of others at the world’s biggest tech event.Tech World CES Keynote to showcase Lenovo’s role as An Official Technology Partner of Sphere Studios Lenovo (HKSE: 992) (ADR: LNVGY) and Sphere Entertainment Co. (NYSE: SPHR) announced today that, for the first time ever, Lenovo’s annual global innovation event, Tech World, will take center stage at Sphere in Las Vegas on the opening day of CES® 2026. The 11th annual Tech World will feature Lenovo Chairman and CEO Yuanqing Yang’s CES keynote along with Lenovo’s latest product launches, innovations, proofs of concept, and the company’s AI-driven innovation strategy for the coming years. The event at Sphere, which will showcase content created exclusively for Lenovo by Sphere Studios, Sphere’s in-house immersive content studio, marks the second consecutive year that a CES keynote will be de
In our pressroom you can read all our latest releases, find our press contacts, images, documents and other relevant information about us.
Visit our pressroom